SCH5910F Heavy Duty Fire-Rated Rim Exit Device / Grade 1 / For wide stile and flush doors use

  • SCH5910F heavy duty fire-rated rim exit devices for wide stile and flush doors use are used on single doors/double doors with mullions. (Fire rated device must use on 4′ x 8′ (1219 mm x 2438 mm) single or 8′ x 8′ (2438 mm x 2438 mm)
  • The Exit devices are available in the following finishes:
    605, 630, 689, 690

Fire-Rated Rim Exit Device:

Heat-Resistant Materials; UL Fire Door Hardware Certification; Durable Latching Mechanism; No Dogging Mechanism; Push Bar for Egress.

Why Is Fire-Rated Rim Exit Device Required?

Stairwell Doors; Corridors in Fire Zones; Fire-Rated Barriers, etc.

Device Head Cover Stainless steel, non-ferrous alloy
Chassis Steel, plated
Mechanism Housing Steel, or stainless steel
Push Bar Steel, or stainless steel
End Cap Steel, or stainless steel
Latch Bolt 100% stainless steel, deadlocking type, 11/16″ (17 mm) throw
Deadlocking Latch 100% stainless steel 5/8″ (16 mm) throw
Strikes SCH531&SCH532 Rim (panic rated), SCH533 Rim (fire rated)
Handing Non-handed
Mounting Fasteners Machine screws furnished standard, Sex Nut and Bolt (SNB) are required to use for wood doors. Order SNB separately.
Dogging* Hex key dogging standard (Allen-type key furnished)
Dogging Options Cylinder dogging or Less dogging
Finish 605, 630, 689, 690, four finishes
Device Lengths Short (36″): 33 15/32″ (850 mm)
Long (48″): 1137 mm ( 44 3/4″ )
UL Listed For Panic Hardware (original listed model no.: SCH500SA)
For fire Exit Hardware (original listed model no.: SCH500AF)

Short (36″): 33 15/32″ (850 mm)
Long (48″): 45 3/4″ (1137 mm)

Universal curved lip, non-handed, 818 (panic), 828 (fire), Optional 831 (panic) or 832 (fire) flat ANSI Strike for door pairs with overlapping astragal 7/8″ (22 mm lip)


SCH531 Strike Shim

Supplied with the SCH532 strike. This 1/8″ thick shim is designed for doors with a 1/2″ stop to ensure the correct distance between the device latch and the surface-mounted strike. If the frame has a 5/8″ stop, the shim is not required.

SCH532 Panic Rim strike

Surface applied. Standard on SCH5000 Series panic rim exit devices. Stainless Steel, With a plated roller.


SCH533 Fire Rim Strike

Surface applied. Standard on SCH5000 Series fire rim devices. It is 100% stainless steel including a roller.

Parts Material

1. Auxiliary Guarded Latch Stainless steel
2. Latch bolt, 3/4″ (19 mm) throw Stainless steel
3. Chassis Cover Nonferrous alloy or stainless steel
4. Push Bar Steel, or stainless steel
5. Push Bar End Cap Steel, or stainless steel
6. Push Bar Trim Steel, or stainless steel
7. Mechanism Housing (or Device Body) Steel, or stainless steel
8. Dogging Plate (or Device Body) Steel, or stainless steel
9. End Cap Steel, or stainless steel

Device Length

The devices are precut for 36″ (914 mm) and 48″ (1219 mm) wide doors (standard shipping size), no additional cutting is necessary.

Short 36″: Device Length is 32 15/16 (837 mm) for 3′ (914 mm) door use, with short push bar.

Long 48″: Device length is 45½″ (1155.8 mm) for 4′ (1219 mm) door use, with long push bar.

For narrow doors, trim the “A” portion to fit a door width minus 2″ (51 mm).

Standard vertical rods fit 7′ (2134 mm) panic exit doors or 8′ (2438 mm) fire exit doors. For taller doors, specify the height when ordering to receive a longer top rod.

  • UL/cUL Listed : UL listed as Panic Exit Hardware or 3-hour Fire Exit Hardware
  • ANSI Certified : Devices are ANSI A156.3 – 2014 Grade 1

Related Products