SCH5710F Light Duty Designed Fire-Rated Rim Exit Device / Wide Stile / Grade 1

  • SCH5710F wide stile designed light duty fire-rated rim exit devices grade 1 are ideal for single doors/double doors with mullions. Fire-rated devices must be used on 4′ x 8′ (1219 mm x 2438 mm) single or 8′ x 8′ (2438 mm x 2438 mm) double fire-labeled doors.
  • The Exit devices are available in the following finishes:
    US3, US20A, US28, US32D.

Fire-Rated Rim Exit Device:

Heat-Resistant Materials; UL Fire Door Hardware Certification; Durable Latching Mechanism; No Dogging Mechanism; Push Bar for Egress.

Why Is Fire-Rated Rim Exit Device Required?

Stairwell Doors; Corridors in Fire Zones; Fire-Rated Barriers, etc.

Locking Mechanism

  • Uses a rim-mounted latch that secures the door by engaging the door frame directly.
  • The latch is surface-mounted, with a simpler mechanism compared to a mortise lock.
Minimum Stile Width Minimum Stile width: 3 1/2″ (90 mm)
Latch Bolt 100% stainless steel, deadlocking type, 11/16″ (17 mm) throw
Deadlocking Latch 100% stainless steel 5/8″ (16 mm) throw
Strikes SCH531&SCH532 Rim (panic rated); SCH533 Rim (fire rated)
Dogging Kit Panic Device: Standard hex key dogging (Allen-type key included).
Fire Device: No mechanical dogging (dogging is not allowed on fire-rated).
Dogging Options Cylinder dogging or less dogging
Mounting Fasteners Machine screws furnished standard, Sex Nut and Bolt (SNB) are required to use for wood doors. Order SNB separately.
Head Cover Stainless steel, non-ferrous alloy
Chassis Steel, plated
Finish US3, US20A, US28, US32D
Mechanism Housing Steel, or stainless steel

Short (36″): 32 11/16″ (830 mm)
Long (48″): 44 23/32″ (1136 mm)

Universal curved lip, non-handed, 818 (panic), 828 (fire), Optional 831 (panic) or 832 (fire) flat ANSI Strike for door pairs with overlapping astragal 7/8″ (22 mm lip)


SCH531 Strike Shim

Supplied with the SCH532 strike. This 1/8″ thick shim is designed for doors with a 1/2″ stop to ensure the correct distance between the device latch and the surface-mounted strike. If the frame has a 5/8″ stop, the shim is not required.

SCH532 Panic Rim strike

Surface applied. Standard on SCH5000 Series panic rim exit devices. Stainless Steel, With a plated roller.


SCH533 Fire Rim Strike

Surface applied. Standard on SCH5000 Series fire rim devices. It is 100% stainless steel including a roller.

Parts Material

1. Auxiliary Guarded Latch Stainless Steel
2. Latch bolt, 3/4″ (19mm) throw Stainless Steel
3. Chassis Cover Nonferrous Alloy or Stainless Steel
4. Push Bar Steel, or Stainless Steel
5. Dogging Plate Steel, or Stainless Steel
6. End Cap Steel, or Stainless Steel
7. Mechanism Housing (or device body) Steel, or Stainless Steel

Device Length

The devices are precut for 36″ (914 mm) and 48″ (1219 mm) wide doors (standard shipping size), no additional cutting is necessary.

Short 36″: Device Length is 32 11/16(830 mm) for 3′ (914 mm) door use, with short push bar.

Long 48″: Device length is 44 23/32 (1136 mm) for 4′ (1219 mm) door use, with long push bar.

For narrow doors, trim the “A” portion to fit a door width minus 2″ (51 mm).

Standard vertical rods fit 7′ (2134 mm) panic exit doors or 8′ (2438 mm) fire exit doors. For taller doors, specify the height when ordering to receive a longer top rod.

  • Complies with ANSI A156.3 – 2014 Grade 1.
  • Certified to UL 305 standard for panic exit hardware.
  • Certified to UL 10C standard for fire exit hardware.